Welding Equipments
 

TIG / ARC WELDING INVERTERS

PRIMARY

MAINS VOLTAGE

220VAC(+/-15)
1 Phase, 50Hz.

INPUT CURRENT (FULL LOAD)

5 Amp

MAINS FUSE PROTECTION

12A

EFFICIENCY

0.85

POWER CONSUMPTION 100% DUTY CYCLE

3.2KVA

SECONDRY

OPEN CIRCUIT VOLTAGE

72 VDC

OUTPUT CURRENT

5-110 Amp

PROTECTION CLASS

IP23

INSULATION CLASS

B

DUTY CYCLE 100%

80 Amp

COOLING

AF

DIMENSION ( LxWxH )mm

400x200x400

WEIGHT IN KG.

18

TIG / ARC WELDING INVERTERS


 

PRIMARY

MAINS VOLTAGE

220VAC(+/-15)
1 Phase, 50Hz.

INPUT CURRENT (FULL LOAD )

7 Amp

MAINS FUSE PROTECTION

15A

EFFICIENCY

0.85

POWER CONSUMPTION 100% DUTY CYCLE

3.5KVA

SECONDARY

OPEN CIRCUIT VOLTAGE

78 VDC

OUTPUT CURRENT

5-150 Amp

PROTECTION CLASS

IP23

INSULATION CLASS

B

DUTY CYCLE 100%

110 Amp

COOLING

AF

DIMENSION ( LxWxH )mm

400x200x400

WEIGHT IN KG.

23

TIG / ARC WELDING INVERTERS
 
 

PRIMARY

MAINS VOLTAGE

415VAC(+/-15)
3 Phase, 50Hz.

INPUT CURRENT (FULL LOAD)

10 Amp

MAINS FUSE PROTECTION

18A

EFFICIENCY

0.85

POWER CONSUMPTION 100% DUTY CYCLE

6.0KVA

SECONDARY

OPEN CIRCUIT VOLTAGE

78 VDC

OUTPUT CURRENT

5-200 Amp

PROTECTION CLASS

IP23

INSULATION CLASS

B

DUTY CYCLE 100%

160 Amp

COOLING

AF

DIMENSION ( LxWxH )mm

450x250x400

WEIGHT IN KG.

39

POWER SOURCE

TW3000 

PRIMARY

MAINS VOLTAGE

230 Vor 415V AC(+/-15) 3 Phase, 50Hz.  

INPUT CURRENT (FULL LOAD)

12 Amp

MAINS FUSE PROTECTION

20 A

EFFICIENCY

0.85

POWER CONSUMPTION 100% DUTY CYCLE

7.0KVA

SECONDARY

OPEN CIRCUIT VOLTAGE

78 VDC

OUTPUT CURRENT FOR 3 PHASE,
415 V

5 - 300 Amp

OUTPUT CURRENT FOR 230V: SINGLE PHASE 5 - 150 Amp

PROTECTION CLASS

IP23

INSULATION CLASS

B

DUTY CYCLE 100% FOR 3 PHASE

240 Amp

DUTY CYCLE 100% FOR SINGLE PHASE  120 Amp

COOLING

AF

DIMENSION ( LxWxH )mm

450x250x400

WEIGHT IN KG.

48